Frequently Asked Questions

Note: If your question is not answered in this document, we encourage you to contact us toll free at 888-636-2401 or 408-636-2400 x 119. You may also use our online contact form. Your question will be answered by one of our sales specialists.


What is the price of the QuantiFluor™-ST Fluorometer?
The price may vary based on your application(s) and requirements. To receive a quote customized to your needs, use our online quotation form (click here).

What are the primary applications of the QuantiFluor™-ST Fluorometer?
The primary application for the QuantiFluor™-ST Fluorometer are nucleic acid and protein quantitation. A list of the applications include:

DNA Quantitation Dyes, Hoechst 33258
RNA Quantitation Dyes
Protein Quantitation Dyes

What is the sensitivity of the QuantiFluor™-ST Fluorometer?
The QuantiFluor™-ST 's sensitivity is defined in terms of the minimum detection limits of dsDNA and RNA. The QuantiFluor™-ST Fluorometer can detect:

Minimum Detection Limit
Analyte
Using a 10 x 10 mm Cuvette
Using a Minicell
DNA Quantitation Dye
.5 ng/mL
1 ng/mL
DNA - Hoechst 33258 Dye
10 ng/mL
10 ng/mL
RNA Quantitation Dye
1 ng/mL
1 ng/mL
Protein Quantitation Dye
100 ng/mL
N/A

What is the optical configuration of the QuantiFluor™-ST Mini-Fluorometer?
The QuantiFluor™-ST has two dedicated optical channels, UV and BLUE channels.
UV: Ex 365 nm, Em 440-470 nm
BLUE: Ex 460 nm, Em 515-575 nm

What size sample tube/cuvette is standard with the QuantiFluor™-ST Fluorometer?
The standard cuvette size for the QuantiFluor™-ST Fluorometer is 10 x 10 mm plastic cuvettes. With the opional Minicell Adapter, 50 - 250 µl minicell vial can be used.

What is the Minicell Adapter?
The QuantiFluor™-ST Minicell adapter is designed to accommodate the measurement of small volume samples. The design of the focusing lenses allows you to measure fluorescence samples in a much reduced assay volume without losing sensitivity.

Do the sample tubes/cuvettes require minimum volumes? If so, what are they?
Sample tubes do require minimum volumes so that enough sample is exposed to the incoming light. The minimum volumes are as follows:

Cuvette/Tube
Adapter Needed?
Minimum Volume
10 x 10 mm
No
2.0 mL
Minicell
Yes
50 µl

What kind of cuvettes should I use with the QuantiFluor™-ST Fluorometer?
Methacrylate or polystyrene 10 x 10 mm cuvette, or 10 x 10 mm adapter that is designed for fluorescence measurement is appropriate. Due to the natural fluorescence properties of polystyrene, this material is not recommended for UV applications. The following sample tubes and cuvettes are available for purchase from us:

10 x 10 mm Square Polystyrene Cuvette (3.5 mL)
10 x 10 mm Square Methacrylate Cuvette (3.5 mL)
Minicell Borosilicate Glass (50-250 mL)

Can I use a quartz or glass cuvette?
The sample compartment cannot accept glass or quartz cuvettes.

Does the QuantiFluor™-ST Fluorometer have changeable optical filters?
No, the QuantiFluor™-ST Fluorometer does not have changeable optical filters. If the QuantiFluor™-ST Fluorometer's optical configuration does not fit your application requirement, please see information about the GloMax-Multi Jr Single Tube Multimode Reader.

What is the dynamic range of the QuantiFluor™-ST Fluorometer?
The dynamic range of the QuantiFluor™-ST Fluorometer is 4 logs, assay dependent.